Salient
Features:
1.Designed for High
/ Low and On/Off operations
2.Available in Fully Automatic/Semi Automatic/Manual
3.Compact & Proven Design
4.Rugged Construction
5.Simplified Air/oil Ratio
6.Highly Efficient and reliable
7.Easy and Simplified Maintenance.
8.Quick Response to varying loads |
Applications:
1.Steam Boilers
2.Hot Water Boilers
3.Air Heaters
4.Dryers / Ovens
5.Process Heating plants.
6.Thermopacks
7.Hot Air Generators
8.Drum Mix Plants |
|
Burner
Head |
|
B Series -
High / Low/ On/ Off Model Employs two nozzles and
hydraulically operated rapid response of air dampers which
regulates the combustion air at each firing rare.. A unique
system of hinged type maintenance door gives access to the
combustion head for inspection and maintenance. Two stage
operation automatically bring the burner to low fire status
once the desired temperature/pressure is attained and
regulates output between the high and low fire set points,
depending upon the demands of the system.
A series - On/Off model are
suitable for low firing capacity. Built-in blower
alongwith oil pump with head makes it a compact model
enabling it to used on small air heaters, ovens etc where
space is a constraint. |
|
 |
 |
 |

|
|
Blower |
|

|
The air required for the combustion of fuel oil is provided
by the blower. A floor / flange mounted fan provides the air
supply for the system. It has a rectangular outlet which is
flanged and drilled for bolting onto the burner head. The
air is controlled through a regulator located on the suction
side. |
|
Heating Pumping Unit |
|
HPFU are designed to supply fuel oil to the burner at a
predetermined constant temperature and pressure required for
efficient combustion. The principal components are electric
heater which is in an immersion type, motorized rotary gear
oil pump, oil filters, pressure gauges duly interpiped for
the fuel control to the burner. All the above components are
neatly placed and piped on a common base tray making it
compact and coordinated space saving design. |
 |
|
Electrical Control Panel |
The control panel is built into a free standing/wall mounted
cabinet which incorporates a sequence controller, starters
for the fan, fuel pump, and heater. All components are
prewired, input and output circuits being grouped for ease
on onward connection.
|
|
Technical
Specifications of HIT Burner |
|
Model |
Capacity
Liters
Per Hour |
Blower
Motor (H.P.) |
Oil Pump
Motor (H.P.) |
Heater
(K.W) |
Fuel |
Max Appliance
Resistance Allowed
in mm W.G. |
|
H1A |
15 |
0.50 |
0.50 |
- |
HSD / LDO |
80 |
|
H3A |
30 |
1.00 |
0.50 |
2.00 |
LDO / FO |
80 |
|
H4A |
45 |
1.50 |
0.50 |
3.00 |
LDO / FO |
100 |
|
H6A |
60 |
2.00 |
1.00 |
- |
HSD / LDO |
100 |
|
H6B |
70 |
3.00 |
1.00 |
4.50 |
LDO
/ FO |
100 |
|
H9B |
90 |
5.00 |
1.50 |
6.00 |
LDO
/ FO |
110 |
|
H5B |
150 |
5.00 |
2.00 |
9.00 |
LDO
/ FO |
110 |
|
H2B |
200 |
7.50 |
2.00 |
12.00 |
LDO
/ FO |
110 |
|
H25B |
250 |
10.00 |
3.00 |
15.00 |
LDO
/ FO |
110 |
|
H3B |
300 |
12.50 |
3.00 |
18.00 |
LDO
/ FO |
110 |
|
H4B |
400 |
20.00 |
3.00 |
24.00 |
LDO
/ FO |
110 |
|
|